Comfortmaker is the quietest of the ICP labels in every sense: modest marketing, a SoftSound family built around noise, and a name most owners learn only when something breaks.
Schedule today — we’re here 24/7.

Independent service. Bleuwave HVAC is not affiliated with, endorsed by, or an authorized dealer of Comfortmaker. Comfortmaker and related product names are trademarks of their owners. We service and replace this equipment as an independent contractor.
Nobody brags about their Comfortmaker. That is not a criticism of the equipment; it is a fact about the label. Comfortmaker has never spent much on making itself a household name, which means the typical owner discovers the brand the same afternoon they discover the system has quit, standing in the side yard reading a data plate through 110-degree air. If that is you, welcome. Here is what you own.
Comfortmaker is one of the residential labels of International Comfort Products, the Carrier-owned group that also markets Heil, Tempstar and Day and Night. The four labels are built on common platforms and differ mostly in trim, distribution territory and name. When a technician says a Comfortmaker is basically a Heil, they are being more accurate than flippant.
Bleuwave HVAC is an independent service company. We are not affiliated with, endorsed by or an authorized dealer of Comfortmaker, ICP or Carrier. Trademarks belong to their owners. We are paid to fix and replace equipment well, not to move a particular badge.
The split-system families under the Comfortmaker name are Ion, SoftSound and Performance, across air conditioners, heat pumps and gas furnaces. Ion is the communicating tier, where the outdoor unit and the control negotiate capacity with each other. SoftSound is, as the name suggests, the family built around a quieter outdoor unit, which matters more than you would think on a Gilbert or Chandler lot where the condenser sits eight feet from a neighbor's bedroom window. Performance is the conventional line.
Rooftop and slab-mounted packages come as the PGD gas-electric and PHD heat pump, plus related ICP packaged families. Everything else, including specific model numbers, tonnages and efficiency figures: research pending. We will not print what we cannot verify, and we cannot size a system from a page.
A Comfortmaker fails like its siblings, which is to say like everything else in the Valley. The outdoor unit takes the beating: a run capacitor swollen by heat, a contactor pitted by a few hundred thousand cycles, a fan motor that finally gives up in a cabinet that has been 140 degrees inside every afternoon since May. Indoors, the failures are drain lines choked by monsoon humidity and evaporator coils either fouled by dust or leaking at a joint.
There is one Comfortmaker-specific note worth making. Owners of SoftSound equipment sometimes call because the unit has gotten louder, and they are right to. A quiet-by-design system that starts rattling, buzzing or grinding is telling you something specific: a failing fan motor bearing, a loose panel, a compressor beginning to labor. On a system that was never quiet, the same noise gets ignored. The noisy AC page sorts the sounds by what they usually mean.
What you can check yourself: the thermostat mode and setpoint, the filter, a tripped breaker (reset once; if it trips again, stop), ice on the copper lines, and leaves or debris pressed against the condenser. If there is ice, shut the system off and let it thaw before we arrive. Everything inside a panel is our job, not yours.
The absence of brand loyalty is, for once, an advantage. Nobody replaces a Comfortmaker out of sentiment, so the decision can be made purely on numbers: the age of the system, the refrigerant it runs, the cost of the failed part against what is left of the equipment, and how much the house itself is fighting the unit.
For a current-family system under ten years old with a single failed component, the answer is almost always repair. For a legacy system on R-22 with a compressor or coil failure, the answer is almost always replacement, and we will say so before we quote anything. In between is where judgment lives. Rather than rehearse the full argument here, read the repair-vs-replace guide, which lays out how we actually weigh it, and then estimates and financing, which explains what a written scope should contain and that financing on approved credit exists.
One thing we will always add: replacing the box is the moment to fix what the box was compensating for. Undersized returns, leaky attic ducts and a west wall of single-pane glass do not care what brand you buy next. Townhomes in particular tend to have tight equipment closets and short duct runs that deserve a look before a new system goes in.
Here the low profile costs you nothing. Comfortmaker parts are ICP parts, which are stocked for the whole family of labels at Phoenix supply houses. Capacitors, contactors, motors, boards and coils for current families are generally available. Legacy-family parts are the usual gamble, and we check availability before promising a repair date rather than after.
Manufacturer parts warranties typically run for a stated term from installation, conditioned on registration and sometimes on original ownership. Whether your system is inside that term is a matter of paperwork and the date on the data plate, not something a web page can tell you. Bring what you have. We will read it with you and tell you what is likely covered before we proceed.
The maintenance advice is the same for a quiet brand as a loud one: two visits a year, coils cleaned before June, charge and electrical verified, the drain cleared before the humidity comes. Our AC maintenance page lists exactly what a tune-up should include so you can hold any contractor, us included, to it.
Straight answers, no runaround. Don’t see yours? Our team is a phone call away, around the clock.
Comfortmaker is a residential label of International Comfort Products, which is owned by Carrier. It shares platforms and parts with Heil, Tempstar and Day and Night. Bleuwave is an independent service company with no dealer relationship to any of them.
It is a low-profile brand, which is not the same thing. The hardware is shared ICP engineering sold with less marketing behind it. What determines how well it performs in a Phoenix home is sizing, duct connection and refrigerant charge on installation day, and maintenance every year after.
Because something changed. Quiet-by-design equipment that starts humming, rattling or grinding is usually reporting a failing fan motor bearing, a loose panel, a fan blade out of balance from debris, or a compressor under strain. Shut it off if the noise is metallic and have it inspected rather than waiting for the summer to decide for you.
Often the part is physically the same, but interchangeability is confirmed by part number, not by family resemblance. Our technicians verify the match before installing anything, and we source from the same Phoenix supply houses that stock the whole ICP line.
Possibly not. Heat pumps deliver supply air that is warm rather than hot, and they run a defrost cycle on cold mornings that briefly feels like cooling. If the house holds its setpoint, the system is doing its job. If it does not, or the auxiliary heat runs constantly, book a visit. The heat pump page explains what normal looks like.
Registration is done with the manufacturer, usually online, within a deadline after installation, and the terms differ if the deadline is missed. We cannot register equipment on your behalf or confirm coverage from a web page, but we will read your paperwork with you on site and tell you what is likely covered.
Yes. PGD gas-electric and PHD heat-pump packages are common on flat-roof Valley homes, and we diagnose, repair, maintain and replace them. Our rooftop unit page covers how a packaged system differs from a split system and why sun exposure shortens its life.
Same-day appointments across Maricopa and Pinal counties. Pick your city for local pricing pages, reviews and service details.
Book an on-site evaluation. We test the system, read the plate and give you a repair or replacement answer you can check. (480) 863-5855, any hour.