Refrigerant is not a consumable. If your system is low, it has a leak. Here is what the three names on the label mean for repairs, replacements and your options.
Schedule today — we’re here 24/7.

Straight answers, no runaround. Don’t see yours? Our team is a phone call away, around the clock.
Yes, from reclaimed and recycled stock, and the supply shrinks every year. The cost per pound reflects that. Whether it makes sense to buy any depends on the age of the system and where it is leaking, which is the calculation in our R-22 replacement guide.
Not in any practical sense. R-410A runs at much higher pressures and needs a compressor, coils and metering device designed for it, so a conversion is effectively a replacement with extra steps. Drop-in blends for R-22 equipment exist and can keep an old system running with some loss of capacity, but they are a bridge, not a fix.
It carries a mild-flammability classification, which is why equipment built for it includes leak sensors and control logic that runs the blower to disperse any leak. The refrigerant is hard to ignite and the charge is sealed in the system. Installed and serviced by trained technicians, it is safe in a home; the flammability rating changes how it is handled, not whether it belongs there.
Never, on a healthy system. The charge is sealed and does not deplete. If a technician adds refrigerant, the correct next sentence is where the leak is and what it costs to fix it. If that sentence never comes, get a second opinion.
Because a top-off is a temporary patch that costs you refrigerant, a return visit, and eventually a compressor running low on the oil the refrigerant carries. A leak search finds the actual failure so the repair can be quoted flat-rate and done once. Our leak repair page explains what the search involves.
No. The refrigerants are not interchangeable, and the indoor coil, metering device and line set must be rated for the new refrigerant and its safety requirements. A replacement in the new-refrigerant era is nearly always a matched indoor and outdoor set, which is one reason a half-swap is rarely quoted anymore.
Not necessarily. A leaking valve core or a line-set joint on a ten-year-old R-410A system is a straightforward repair. A leaking evaporator coil on a 20-year-old R-22 system is a different conversation. Age, location of the leak and refrigerant type are the three variables, and an on-site diagnosis is the only way to put numbers to them.
Low charge drops the pressure and temperature in the evaporator coil below freezing, so moisture from the air freezes on it instead of draining away. The ice then blocks airflow and the problem feeds itself. Shut the system off, let it thaw completely, and read our frozen coil field note before the technician arrives.
Same-day appointments across Maricopa and Pinal counties. Pick your city for local pricing pages, reviews and service details.
An on-site leak search and charge check give you a real diagnosis, not a top-off, with a flat-rate quote before any work begins.